Description: r4d - rack infrastructure control system
        ========================================
        
        r4d means 'Remote For Device-under-test' and is an infrastructure for
        power-control and console access for multiple Linux Boards that should
        be controlled by a test-infrastructure like jenkins.
        
        r4dd (Remote For Device-under-test Daemon) acts as controlling server for test
        racks. Each Rack contains a serial device server and a power control switch.
        A rack can host several DUTs (device-under-test).
        r4d connects to the serial device server and the power switch to perform
        actions on user request. A user connects to r4d through a SOAP interface.
        
        All available boards, racks, power-controls and serial servers are represented
        in a sqlite database. To show/create or modify the database the 'r4dcfg' tool
        can be used. If the tooling is to limited for your needs we recommend to use
        the 'SQLite Manager Plugin for Firefox' to manually alter the database.
        
        Have also a look at 'https://github.com/ci-rt/libvirt-debian'. This
        project provides a r4d_driver for libvirt. So you can poweron/off the
        boards managed in r4d via libvirt. You can even access the serial
        console of your boards with a command like 'virsh -c
        r4d://localhost:8008 console juno64'
        
        Prerequisite
        ------------
        On Debian systems you can simply run:
        "sudo apt install python3-sqlalchemy python3-pysimplesoap python3-snimpy snmp-mibs-downloader"
        to satisfy all runtime dependencies.
        
        Note, that the 'snmp-mibs-downloader' package is in the non-free section of
        Debian.
        
        Install and run systemd service
        -------------------------------
        Use 'python3 setup.py install' to build and install r4d.
        The so installed systemd service file can be used to control the daemon:
        
            $ systemctl enable r4dd # start it automatically during system boot
            $ systemctl start r4dd  # start it manually (once)
            $ systemctl stop r4dd   # stop it now
        
        Run from source directory
        -------------------------
        Simply start "./r4dd"
        
        Configuration
        -------------
        
        Config file
        ~~~~~~~~~~~
        The listen interface and port and the used database backend can be altered via
        config file that can be passed to r4dd with the -c parameter:
        
            $ r4dd -c /etc/r4d.cfg
        
        The format of /etc/r4d.cfg looks like this:
        
        ::
        
          [r4dd]
          listen=0.0.0.0
          port=8008
          [db]
          echo=0
          uri=sqlite:////var/lib/r4d/r4d.sqlite
          user=None
          password=None
        
        If no file is given, the above config reflects the defaults.
        
        To add a new power switch, serial console server or a testsystem the
        commandline tool "r4dcfg" can be used. This tool should be executed as
        the same user who runs the daemon. The daemon creates the database.
        
        Add rack
        ~~~~~~~~
        Please call "r4dcfg --add-rack NAME LOCATION" where NAME is a unique human
        readable name of the testrack, e.g. 'ci-linux-rack3'. LOCATION describes the
        physical location, e.g. a room number 'SRV07-OU21'.
        
            $ r4dcfg --add-rack ci-linux-rack3 SRV07-OU21
        
        Add power switch
        ~~~~~~~~~~~~~~~~
        Please call "r4dcfg --add-power RACK MODEL HOST" where RACK is the
        human-readable name of the rack the switch is installed in, e.g.
        'ci-linux-rack3', MODEL is the power switch model, e.g. 'pc8210' and HOST the
        hostname or IP of the new power switch, e.g.
        'ci-linux-rack3-power.tec.company.example'
        
        The following models are supported:
        
        - net8x    (Gude Expert Power Control NET 8x)
        - pc8210   (Gude Expert Power Control 8210 / 8211)
        
            $ r4dcfg --add-power ci-linux-rack3 pc8210 ci-linux-rack3-power.tec.company.example
        
        If you get the error "No SNMP response received before timeout"
        you need to activate enable SNMP get for public and set for private in the
        config / SNMP section of the webinterface of the power control switch.
        
        Add serial console server
        ~~~~~~~~~~~~~~~~~~~~~~~~~
        Please call "r4dcfg --add-serial RACK MODEL HOST" where RACK is the
        human-readable name of the rack the serial server is installed in, e.g.
        'ci-linux-rack3', MODEL is the serial server model, e.g. 'PS810' and HOST the
        hostname or IP of the new serial server, e.g.
        'ci-linux-rack3-serial.tec.company.example'
        
        The following model is supported:
        - ps810    (Sena Pro Series PS810)
        
            $ r4dcfg --add-serial ci-linux-rack3 PS810 ci-linux-rack3-serial.tec.company.example
        
        Add device under test
        ~~~~~~~~~~~~~~~~~~~~~
        Please call "r4dcfg --add-board RACK SLOT NAME" where RACK is the
        human-readable name of the rack the 'device under test'is installed in, e.g.
        'ci-linux-rack3', SLOT is the position inside the rack, e.g. '5' for slot number
        5. Slot 5 should be connected with port 5 of the powercontrol switch and port 5
        of the serial server. NAME is the name of the new device under test, e.g.
        'juno64'
        
            $ r4dcfg --add-board ci-linux-rack3 5 juno64
        
        Inspect database and testing
        ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
        Use
        
            $ r4dcfg --show-db
        
        to get an overview of the configured infrastructure.
        
            $ r4dcfg --list-boards
        
        ::
        
          ID[1]: el9jyJpAN1aZNTGiuQpB6g==
          Name: juno64      Rack: ci-linux-rack3     Port: 5 serial: ci-linux-rack3-serial.tec.company.example:7005
        
        The 'ID[1]' means board is powered, 'ID[0]' board is poweroff and 'ID[-1]'
        power state of bard is unknown.
        
        To switch the powerstate off a board, the following commands can be used:
        
            $ r4dcfg --poweron juno64
            $ r4dcfg --poweroff juno64
            $ r4dcfg --powercycle juno64
        
        This commands are for testing the infrastructure! To control the boards from
        e.g. jenkins or other systems in your LAN please use libvirt as described in
        the intro!
        
        Move board
        ~~~~~~~~~~
        To move a board to a different rack and/or slot use "r4dcfg --move-board
        DST_RACK DST_SLOT NAME" where DST_RACK is the name of the new rack the board
        should be placed in, DST_SLOT is the number of the new slot it should be placed
        and NAME is the name of the board that should be moved. If DST_RACK is the same
        as the current rack the board is placed in the command can be used to move the
        board to a different slot in the same rack. E.g. to move the juno64 board into
        slot 8 use the following command:
        
            $ r4dcfg --move-board ci-linux-rack3 8 juno64
        
        Delete board
        ~~~~~~~~~~~~
        To delete a board from the infrastructure you should use "r4dcfg --delete-board
        NAME" where NAME is the name of the board to be removed. E.g. to remove the
        juno64 board from the infrastructure use:
        
            $ r4dcfg --delete-board juno64
        